Cirrus-logic EP93xx Manual do Utilizador Página 573

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 824
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 572
DS785UM1 15-15
Copyright 2007 Cirrus Logic
UART2
EP93xx User’s Guide
1
5
1
5
Default:
0x0000_0000
Definition:
UART Interrupt Identification and Interrupt Clear Register. Interrupt status is
read from UART2IntIDIntClr. A write to UART2IntIDIntClr clears the modem
status interrupt. All the bits are cleared to 0 when reset.
Bit Descriptions:
RSVD: Reserved. Unknown During Read.
RTIS: Receive Timeout Interrupt Status. This bit is set to “1” if the
receive timeout interrupt is asserted.
TIS: Transmit Interrupt Status. This bit is set to “1” if the
transmit interrupt is asserted.
RIS: Receive Interrupt Status. This bit is set to “1” if the receive
interrupt is asserted.
MIS: Modem Interrupt Status. This bit is set to “1” if the modem
status interrupt is asserted.
UART2IrLowPwrCntr
Address:
0x808D_0020 - Read/Write
Default:
0x0000_0000
Definition:
UART IrDA Low Power Divisor Register. This is an 8-bit read/write register
that stores the low-power counter divisor value used to generate the
IrLPBaud16 signal by dividing down of UARTCLK. All the bits are cleared to 0
when reset.
Bit Descriptions:
RSVD: Reserved. Unknown During Read.
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
RSVD
1514131211109876543210
RSVD ILPDV
Vista de página 572