CS1630/31
DS954F3 41
6.29 Configuration 47 (Config47) Address 79
76543210
OCP OLP OVP BOP COP LLP EEOTP IOTP
Number Name Description
[7] OCP
Configures second stage primary side overcurrent protection.
0 = Enable
1 = Disable
[6] OLP
Configures second stage primary side open loop protection (R
Sense
Short Pro-
tection).
0 = Enable
1 = Disable
[5] OVP
Configures second stage secondary side overvoltage protection (Output Open
Circuit Protection).
0 = Enable
1 = Disable
[4] BOP
Configures boost overvoltage protection.
0 = Enable
1 = Disable
[3] COP
Configures clamp overpower protection.
0 = Enable
1 = Disable
[2] LLP
Configures line link protection.
0 = Enable
1 = Disable
[1] EEOTP
Configures external overtemperature protection.
0 = Enable
1 = Disable
[0] IOTP
Configures internal overtemperature protection.
0 = Enable
1 = Disable